The impact of povidone-iodine pocket irrigation use on pacemaker and defibrillator infections
Dhanunjaya Lakkireddy1, Srilaxmi Valasareddi, Kay Ryschon
1Cleveland Clinic Foundation, Cleveland, Ohio, USA.
Background:
Infection is a devastating complication of permanent pacemakers (PMs) implantable cardioverter defibrillators (ICDs). Many implanting physicians commonly use povidone-iodine solution to irrigate the device pocket before implanting the device. We sought to assess if such a measure would alter the rate of infection.
Methods:
A total of 2,564 consecutive patients who received implantable PM or ICD devices between 1994 and 2002 were studied. Povidone-iodine was used for pocket irrigation in 53% and saline in 47%. A total of 18 (0.7%) patients developed pocket infections with 0.7% (10/1,359) in povidone-iodine (group I) and 0.6% (8/1,205) in saline (group II) pocket irrigation (p = ns). Groups I and II were studied for various clinical and demographic variables described in the results section.
Results:
There was no statistical difference in the baseline demographic and clinical characteristics between groups I and II, respectively. ICDs were most frequently infected than PMs (56% vs 44%). Most (83%) of the devices were dual chamber. Reopening of the pocket for either lead or generator replacement had a higher incidence of infection than new implants (61% vs 39%). There was no difference in the use of preimplantation antibiotic prophylaxis. Late (61%) and deep pocket infections (78%) were more common than early (39%) and superficial infections (22%). Blood cultures were positive in 67% and Staphylococcus aureus was the common most pathogen (50%). The mean duration of antibiotics use after the diagnosis of device infection was 35 +/- 23 days with 72% requiring device explantation. The device was reimplanted on the contralateral side in 56% cases. One patient in each group died due to device infection and related complications. No significant allergy to iodine was seen in either group.
Conclusion:
Povidone-iodine irrigation of the subcutaneous pocket did not alter the rates of pocket infection after pacemaker/defibrillator implantation.
Insights
Povidone-iodine pocket irrigation did not change infection rates for pacemaker or defibrillator implants. This study found no significant difference in infection rates between povidone-iodine and saline irrigation methods.
Area of Science:
- Cardiology
- Infectious Disease Prevention
- Medical Device Implantation
Background:
- Device infection is a serious complication of permanent pacemakers (PMs) and implantable cardioverter defibrillators (ICDs).
- Physicians often irrigate the device pocket with povidone-iodine before implantation.
- The effectiveness of povidone-iodine irrigation in reducing infection rates is unclear.
Purpose of the Study:
- To evaluate whether povidone-iodine irrigation of the subcutaneous pocket affects the incidence of device infection.
- To compare infection rates between povidone-iodine and saline irrigation in patients receiving PM or ICD devices.
Main Methods:
- A retrospective study of 2,564 patients who received PM or ICD devices between 1994 and 2002.
- Patients were divided into two groups: povidone-iodine pocket irrigation (53%) and saline pocket irrigation (47%).
- Infection rates and clinical/demographic variables were compared between the groups.
Main Results:
- No statistically significant difference in pocket infection rates was observed between the povidone-iodine (0.7%) and saline (0.6%) groups.
- Infections were more common in implantable cardioverter defibrillators (ICDs) than pacemakers (PMs) and occurred more frequently with device reopening than new implants.
- Late and deep pocket infections were more prevalent, with Staphylococcus aureus being the most common pathogen.
Conclusions:
- Povidone-iodine irrigation of the subcutaneous pocket does not reduce the rate of pocket infection following pacemaker/defibrillator implantation.
- The findings suggest that current irrigation practices may not significantly impact infection prevention in these procedures.
More Related Videos
05:43Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
Published on: April 19, 2024
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Hand hygiene
Hand washing...
Endocarditis IV: Nursing Management
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Endocarditis III: Medical Management
Endocarditis I: Introduction
PPE Use in Healthcare Settings II: Doffing