Related Experiment Video
Updated: Aug 16, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Determination of trace concentrations of bromate in municipal and bottled drinking waters using a hydroxide-selective
Brian M De Borba1, Jeff S Rohrer, Chris A Pohl
1Dionex Corporation, 1228 Titan Way, Sunnyvale, CA 94088-3606, USA. brian.deborba@dionex.com
Abstract:
The International Agency for Research on Cancer determined that bromate is a potential human carcinogen, even at low micro/l levels in drinking water. Bromate is commonly produced from the ozonation of source water containing naturally occurring bromide. Traditionally, trace concentrations of bromate and other oxyhalides in environmental waters have been determined by anion exchange chromatography with an IonPac AS9-HC column using a carbonate eluent and suppressed conductivity detection, as described in EPA Method 300.1 B. However, a hydroxide eluent has lower suppressed background conductivity and lower noise compared to a carbonate eluent and this can reduce the detection limit and practical quantitation limit for bromate. In this paper, we examine the effect of using an electrolytically generated hydroxide eluent combined with a novel hydroxide-selective anion exchange column for the determination of disinfection byproduct anions and bromide in municipal and bottled drinking water samples. EPA Methods 300.1 B and 317.0 were used as test criteria to evaluate the new anion exchange column. The combination of a hydroxide eluent with a high capacity hydroxide-selective column allowed sub-microg/l detection limits for chlorite, bromate, chlorate, and bromide with a practical quantitation limit of 1 microg/l bromate using suppressed conductivity detection and 0.5 microg/l using postcolumn addition of o-dianisidine followed by visible detection. The linearity, method detection limits, robustness, and accuracy of the methods for spiked municipal and bottled water samples will be discussed.
More Related Videos
06:52Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron (Oxy)Hydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Related Concept Videos
Ion-Exchange Chromatography
Titration of Polyprotic Base with a Strong Acid
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Strong Acid and Base Solutions
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as: