Related Experiment Video
Updated: Aug 16, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Comparisons of disposable and conventional silver working electrode for the determination of iodide using
Lina Liang1, Yaqi Cai, Shifen Mou
1Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing 100085, China.
Abstract:
The paper compared the performance of two kinds of silver working electrode in electrochemical detector-the disposable and conventional electrode for the determination of iodide using high-performance anion-exchange chromatography (HPAEC) hyphenated with pulsed amperometric detection (PAD). The comparisons were carried out on the time of equilibration, long and short-term reproducibility, limits of detection and linearity of calibration. Results showed that disposable working electrode manifested equal or better results than conventional working electrode and could be used for iodide analysis. Besides, the disposable electrode could work for consecutive 2660 min (about 44 h, 10 min needed for each run) with no degradation. Due to its "disposable" property, disposable working electrode could be discarded if the detection sensitivity decreased to 80% so the time for polishing and reconditioning was spared and good reproducible results could be obtained. At last, the disposable electrode was applied for the determination of iodide in soil and sea water samples with the spiked recovery ranging from 96-104% and the detection limit of 0.5 microg/L (10 microL injection, three times of the baseline noise).
More Related Videos
07:23Fabrication of Thin Film Silver/Silver Chloride Electrodes with Finely Controlled Single Layer Silver Chloride
Published on: July 1, 2020
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Ion-Exchange Chromatography
Precipitation Titration Curve: Analysis
Electrodeposition
Electrodeposition can...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Redox Titration: Iodimetry and Iodometry
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: