Related Experiment Video
Updated: Aug 16, 2026

Porcine Normothermic Isolated Liver Perfusion
Published on: June 9, 2023
Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter
Gerard J Myers1, Ken Gardiner, Steve N Ditmore
1Cardiovascular Perfusion Services, QEII Health Sciences Center, Halifax, Nova Scotia. edit@ns.sympatico.ca
Abstract:
The use of arterial line filters has long been a standard of practice in the field of cardiopulmonary bypass. Sorin Biomedica has designed an adult hollow-fiber oxygenator that not only incorporates their Mimesys biomimicry coating technology but also has a 40-micron arterial filter as an integrated component of this unique membrane oxygenator. We did a prospective, randomized clinical trial of 54 Synthesis coated oxygenators and compared them with 54 uncoated Monolyth Pro oxygenators, the latter of which incorporated an external arterial line filter with a standard bypass loop There were few statistically significant differences found between the Synthesis group and the Monolyth group with regard to pressure differentials, hemodynamic resistance, and platelet drop. The Synthesis oxygenator did require less priming volume, but the amount was not significant. Platelet counts with the Phosphorylcholine coated Synthesis oxygenators, using crystalloid perfusates, was similar to our previously published data on platelet protection and Albumin perfusates. We conclude that the Sorin Synthesis oxygenator appears to have better flow characteristics than the Monolyth oxygenator, with the potential for lower priming volumes. The most clinically significant benefit comes from the elimination of the arterial filter bypass loop and the avoidance of inverting the arterial filter during priming.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Bioreactor Controls-II
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...