[Wall relative humidity: a simple and reliable index for predicting Stachybotrys chartarum infestation in dwellings]
Denis Charpin1, Sandrine Boutin-Forzano, Sophie Chabbi
1Service de Pneumologie-allergologie, Hôpital Nord, Marseille.
Abstract:
As the indoor mold Stachybotrys chartarum (SC) has been linked to serious health disorders, its identification in water-damaged dwellings is of utmost importance. The aim of this work was to compare wall relative humidity (RH) measurements with the results of mold identification studied on 458 samples collected from 100 dwellings. Mold identification was based on direct microscopic examination of wall samples collected by the gummed paper technique. Mean (+/- SD) wall RH (%) was much higher (97.0 +/- 6.1) when SC was identified (30 samples) than when other molds were identified (291 samples, 41.8 +/- 36.9) and when no molds were identified (137 samples, 38.9 +/- 34.8). There was a direct relationship between wall and room-air RH but the scatter of results implies that the latter cannot be used as a surrogate for the former. This study suggests that simple wall RH measurement can serve as a reliable indicator of SC infestation of dwellings.
Insights
High wall relative humidity (RH) reliably indicates Stachybotrys chartarum (SC) mold in homes. Simple RH measurements can detect this significant indoor mold, crucial for health.
Area of Science:
- Environmental microbiology
- Building science
- Public health
Context:
- Stachybotrys chartarum (SC) is an indoor mold linked to health issues.
- Identifying SC in water-damaged homes is critical for occupant health.
- Microscopic examination of wall samples is the standard for mold identification.
Purpose:
- To compare wall relative humidity (RH) measurements with SC mold identification results.
- To assess the reliability of wall RH as an indicator for SC infestation.
- To determine if room-air RH can substitute for wall RH measurements.
Summary:
- 458 wall samples from 100 dwellings were analyzed for mold via microscopy.
- Mean wall RH was significantly higher (97.0%) when SC was present compared to other molds (41.8%) or no mold (38.9%).
- Wall RH showed a direct correlation with room-air RH, but room-air RH is not a reliable surrogate for wall RH.
Impact:
- Simple wall RH measurements can serve as a reliable indicator of SC mold infestation.
- This finding aids in the early detection and management of hazardous indoor mold.
- Facilitates proactive measures to mitigate health risks associated with SC exposure.