Fluid-structure interaction effects on sac-blood pressure and wall stress in a stented aneurysm
1Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910, USA.
Abstract:
An aneurysm is a local artery ballooning greater than 50% of its nominal diameter with a risk of sudden rupture. Minimally invasive repair can be achieved by inserting surgically a stent-graft, called an endovascular graft (EVG), which is either straight tubular curved tubular or bifurcating. However post-procedural complications may arise because of elevated stagnant blood pressure in the cavity, i.e., the sac formed by the EVG and the weakened aneurysm wall In order to investigate the underlying mechanisms leading to elevated sac-pressures and hence to potentially dangerous wall stress levels and aneurysm rupture, a transient 3-D stented abdominal aortic aneurysm model and a coupled fluid-structure interaction solver were employed. Simulation results indicate that, even without the presence of endoleaks (blood flowing into the cavity), elevated sac pressure can occur due to complex fluid-structure interactions between the luminal blood flow, EVG wall, intra-sac stagnant blood, including an intra-luminal thrombus, and the aneurysm wall. Nevertheless, the impact of sac-blood volume changes due to leakage on the sac pressure and aneurysm wall stress was analyzed as well. While blood flow conditions, EVG and aneurysm geometries as well as wall mechanical properties play important roles in both sac pressure and wall stress generation, it is always the maximum wall stress that is one of the most critical parameters in aneurysm rupture prediction. All simulation results are in agreement with experimental data and clinical observations.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Structure of Blood Vessels
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Mitral Stenosis I: Introduction
Heart Failure II: Pathophysiology
Aneurysm I: Introduction