Effects of extremely low frequency electromagnetic fields on membrane-associated enzymes

A Morelli1, S Ravera, I Panfoli

  • 1Department of DIBISAA, University of Genoa, viale Benedetto XV, 3 Genova 16131, Italy.

Related Concept Videos

Enzyme-linked Receptors01:00

Enzyme-linked Receptors

Enzyme-linked receptors are proteins that act as both receptor and enzyme, activating multiple intracellular signals. This is a large group of receptors that include the receptor tyrosine kinase (RTK) family. Many growth factors and hormones bind to and activate the RTKs.
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Protein Diffusion in the Membrane01:24

Protein Diffusion in the Membrane

Proteins show rotational as well as lateral diffusion across the membrane. The lateral diffusion of proteins was confirmed through the cell fusion experiment where mouse and human cells were fused, resulting in hybrid cells. When the human and mouse cells fused, the specific membrane proteins on human and mouse cells were marked with the red and green-fluorescent markers, respectively. Initially, the red and green fluorescence was located on the respective hemisphere of the cell. As time...
Mechanisms of Membrane-bending01:15

Mechanisms of Membrane-bending

The living membranes are flexible due to their fluid mosaic nature; however, their bending into different shapes is an active process regulated by specific lipids and proteins. The membrane bending can be transient as seen in vesicles or stable for a long time as in microvilli. Cells regulate the size, location, and duration of the membrane curvature.
Membrane bending can happen due to intrinsic changes in lipid composition or extrinsic association with different proteins. The proteins involved...
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and the equilibrium...