Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Band acceleration device for enhanced selectivity with tandem-column gas chromatography
Mark Libardoni1, Megan McGuigan, Young J Yoo
1Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA.
Abstract:
An electrically heated and air cooled metal sheath surrounding the first 50 cm of the second column in a series-coupled, capillary-column ensemble of a non-polar and a polar column is used to obtain enhanced isothermal separation of component pairs that are separated by the first column in the ensemble but co-elute from the ensemble by virtue of the different selectivity of the two columns. As the first of the two components passes into the second column, a current pulsed through the metal sheath rapidly heats the first 50 cm of the second column thus accelerating the band for the first component. Ensemble retention-time shifts of several seconds are easily obtained. The device is then rapidly cooled to quiescent oven temperature by a flow of pressured air through the space between the metal sheath and the fused silica capillary column and an additional flow through a larger, co-axial plastic tube. Both heating and cooling require only a few seconds. If substantial cooling of the device occurs before the band for the second component enters the device, the band experiences less thermally-induced acceleration with the result that the separation of the two targeted components is enhanced in the ensemble chromatogram with no significant change in the pattern of peaks for the other mixture components. If the device is cooled to a temperature below oven temperature before the arrival of the band for the second component, this band will be slowed, and further enhancement of separation is achieved in the ensemble chromatogram. A band trajectory model, based on retention factor versus temperature data for the two components in the two columns, is used to predict peak separation and to aid in the selection of temperature-pulse initiation times.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Tandem Mass Spectrometry
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.