Related Experiment Video
Updated: Aug 16, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
[Effects of different mechanical ventilation methods on oxygenation and shunt fraction in patients undergoing valve
Fei Ren1, Hong-wei Cai, He-na Jiao
1Department of Anesthesiology , Xiangya Hospital, Central South University, Changsha 410008, China. renfei1970@sina.com
Objective:
To determine the effects of different mechanical ventilation on oxygenation and shunt fraction in patient undergoing valve replacement.
Methods:
Thirty ASA II-III patients (12 males, 18 females), aged 25-56 years, undergoing valve replacement were randomly divided into 3 groups according to the mechanical ventilation method. Anesthesia was induced with midazolam 0.1 mg/kg, fentanl 10 microg/kg,vecuronium 0.1 mg/kg,and etomidate 0.3 mg/kg. Valve replacement was performed with moderate hypothermic cardiopulmonary bypass( CPB). The patients were mechanically ventilated with pure oxygen and I:E ratio 1:2. Group A (TV = 7 ml/kg, f=12 bpm) ,Group B (TV=5 ml/kg, f=15 bpm), and Group C (TV=7 ml/kg, f=15 bpm). ECG, BP, SPO2, and CVP were routinely monitored. Blood samples were taken from the radial artery and pulmonary artery at 30 min after the induction of anesthesia, 10 min before CPB, and the end of operation for blood gas analysis. Respiratory index (P(A-a) DO2/PaO2), and Qs/Qt were calculated.
Results:
There was no significant difference in age, weight, duration of operation of CPB time and aortic cross-clamping time among the 3 groups. At the end of operation, PaO2 decreased significantly, P (A-a)DO2, RI, and Qs/Qt increased significantly in group A, while there was no significant change in group B and group C. At the end of the operation, PaCO2 was lower than the baseline value (< 35 mmHg) in Group A, but it was normal in Group B and group C.
Conclusion:
The mechanical ventilation method of lower tidal volume and higher respiratory rate might increase the oxygenation and decrease shunt fraction and might be more suitable in patients undergoing valve replacement.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mitral Stenosis IV: Nursing Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...