Electrocardiogram, hemodynamics, and core body temperatures of the normal freely moving cynomolgus monkey by remote radiotelemetry
Related Experiment Video
Updated: Aug 16, 2026

Implantation of Radiotelemetry Transmitters Yielding Data on ECG, Heart Rate, Core Body Temperature and Activity in Free-moving Laboratory Mice
Published on: November 21, 2011
David V Gauvin1, Larry P Tilley, Francis W K Smith
1Safety Pharmacology, MPI Research, Inc., 54943 North Main St., Mattawan, MI 49071-9399, USA.
Introduction:
The objectives of this study were to provide baseline normative values for circadian changes in the time-series data collected over the course of a normal day in laboratory-housed monkeys, and to assess the relative efficiency of standard correction formulas to correct for the variations in QT interval durations and heart rate functions.
Methods:
Ninety-nine cynomolgus monkeys (58 M, 41 F) were equipped with radiotelemetry transmitters and continuously monitored, while freely moving in their home cages. Electrocardiograms (ECGs), hemodynamic parameters (diastolic, systolic, and mean arterial pressures) as well as core body temperatures were recorded for 22 h from each of 99 monkeys. ECGs were measured by a computerized waveform analysis program and reported as RR, PR, QRS, and QT intervals.
Results:
Blood pressures and core body temperatures demonstrated a normal circadian variation in their respective values over the 22 h monitoring period. Standard study-specific correction formulas failed to satisfactorily normalize the relationship between heart rate and QT intervals in the cynomolgus monkeys. In contrast, a subject-specific correction method based on analysis of covariance produced a linear function between heart rates and QT intervals and provided QTc values within the normal range of actual, recorded data.
Discussion:
We believe these procedures represent the contemporary industry's preferred practice for measuring such parameters under the ICH guidelines, and are amenable to routine use in a variety of other relevant safety/efficacy studies.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrophysiology of Normal Cardiac Rhythm
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

