Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
River habitat quality from river velocities measured using acoustic Doppler current profiler
1National Sedimentation Laboratory , US Department of Agriculture Agricultural Research Service , PO Box 1157, 598 McElroy Drive, Oxford, Mississippi 38655-1157, USA. dshields@ars.usda.gov
Abstract:
Prior research has demonstrated the utility of metrics based on spatial velocity gradients to characterize and describe stream habitat, with higher gradients generally indicative of higher levels of physical heterogeneity and thus habitat quality. However, detailed velocity data needed to compute these metrics are difficult to obtain. Acoustic Doppler current profilers (ADCP) may be used to rapidly collect detailed representations of river velocity fields. Herein we demonstrate use of ADCP to obtain ecologically relevant data and compute associated metrics. Data were collected from four reaches of the Little Tallahatchie River in northern Mississippi. Sampled reaches were selected to observe velocity regimes associated with three distinctly different conditions: downstream from a major flow obstruction (a low weir), downstream from the apices of each of two bends, and within an extremely long, straight reach created by channelization. Three-dimensional velocity data sets from each site were used to compute metrics of habitat quality proposed by others. A habitat metric based on the presence of rotational flow in the vertical plane proved to be the best discriminator among conditions within the sampled reaches. Two of four habitat quality metrics computed from these measured velocities were greatest for the sharpest meander bend. ADCP hold great potential for study of riverine physical aquatic habitats, particularly at the reach scale. Additional work is needed to develop generally applicable field protocols and data reduction tools. Specifically, guidelines for ADCP settings and configuration appropriate for a range of riverine site conditions must be developed. Advances in instrumentation are needed to allow collection of information in closer proximity to the free surface and solid boundaries.
Related Concept Videos
Rapidly Varying Flow
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Weir: Problem Solving
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: