Related Experiment Video
Updated: Aug 16, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
A finite element comparison between the mechanical behaviour of rigid and resilient oral implants with respect to
Amaya Pérez del Palomar1, Alberto Arruga, José Cegoñino
1Group of Structural Mechanics and Materials Modeling, Aragón Institute of Engineering Research, University of Zaragoza, Spain. amaya@unizar.es
Abstract:
In this paper, a qualitative comparison between two types of dental implants with respect to their behaviour under immediate loading is presented. This analysis has been carried out using the finite element method. Since micromotions (and not the load) are responsible of the appearance of a fibrous interface avoiding osseointegration, the relative displacement between the bone surface and the implant has been the main variable analyzed at different loading states and for the two implant types here considered. The implants analyzed differ in their mechanical behavior: rigid or resilient. Their main difference lies in the joining between the different pieces that make up the dental system. While in the rigid implant all the pieces are screwed, in the resilient implant a relative displacement between the pieces is allowed, with the additional introduction of a silicone gasket that acts like the periodontal ligament. Both implants were considered with a similar geometry and under two different loading scenarios, one equivalent to the force of chewing applied to a molar and another which corresponds to a premolar. For the resilient implant, a hyperelastic behaviour for the silicone and contact conditions between the different mobile parts of the implant are considered. The displacements of the emerging-body in both designs are also compared with the values obtained by several authors. However, the results show that both implants fulfill the constraint of the immediate loading protocol. The micromotions of the resilient implant are lower to those of the rigid one, favouring therefore a good osseointegration process while keeping the stresses in the implant under admissible maximum values.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:16Finite Element Analysis Model for Assessing Expansion Patterns from Surgically Assisted Rapid Palatal Expansion
Published on: October 20, 2023