Related Experiment Video
Updated: Aug 16, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Quantitative diagnosis of stress-induced myocardial ischemia using analysis of contrast echocardiographic parametric
Eran Toledo1, Lawrence D Jacobs, Joseph A Lodato
1Noninvasive Cardiac Imaging Laboratory, Department of Medicine, Section of Cardiology, University of Chicago, MC5084, 5841 S. Maryland Avenue, Chicago, IL 60637, USA.
Aims:
Parametric imaging of myocardial perfusion provides useful visual information for the diagnosis of coronary artery disease (CAD). We developed a technique for automated detection of perfusion defects based on quantitative analysis of parametric perfusion images and validated it against coronary angiography.
Methods And Results:
Contrast-enhanced, apical 2-, 3- and 4-chamber images were obtained at rest and with dipyridamole in 34 patients with suspected CAD. Images were analyzed to generate parametric perfusion images of the standard contrast-replenishment model parameters A, beta and A.beta. Each parametric image was divided into six segments, and mean parameter value (MPV) was calculated for each segment. Segmental MPV ratio between stress and rest was defined as a flow reserve index (FRI). Receiver operating characteristics (ROC) analysis was used in a Study group (N=17) to optimize FRI threshold and the minimal number of abnormal segments per vascular territory (LAD and non-LAD), required for automated detection of stress-induced perfusion defects. The optimized detection algorithm was then tested prospectively in the remaining 17 patients (Test group). LAD and non-LAD stenosis >70% was found in 19 and 17 patients, respectively. In the Study group, FRI threshold was: LAD=0.95 and non-LAD=0.68, minimal number of abnormal segments was four and two, correspondingly. Sensitivity, specificity and accuracy in the Test group were: 75%, 67% and 71% in the LAD, and 75%, 75% and 75% in the non-LAD territories.
Conclusion:
Automated quantitative analysis of contrast echocardiographic parametric perfusion images is feasible and may aid in the objective detection of CAD.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
10:53Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...