Related Experiment Video
Updated: Aug 15, 2026

Rat Model of Normothermic Ex-Situ Perfused Heterotopic Heart Transplantation
Published on: April 21, 2023
The effect of inadequate in situ perfusion in the non heart-beating donor
Muhammed A Gok1, Aftab A Bhatti, John Asher
1Renal Transplant Unit, The Freeman Hospital, University of Newcastle-upon-Tyne, Framlington Place, NE7 7DN Newcastle-upon-Tyne, UK. maasim@doctors.org.uk
Abstract:
In situ aortic perfusion in the nonheart-beating donors (NHBD) is an important procedure to reduce primary warm ischaemic injury prior to formal donor organ retrieval. It allows an interim period to obtain donor family consent and theatre preparation. This study describes our experience of inadequate aortic perfusions resulting from difficult aortic cannulations and associated adverse outcome despite reasonable viability tests. Since 1998, all NHBD in our institution are perfused in situ using a double balloon triple lumen (DBTL) catheter inserted through a femoral artery cut-down procedure. The DBTL catheter is positioned with distal occlusive balloon at the aortic bifurcation using the "pull-back" technique, the proximal occlusive balloon lies above the renal arteries. This provides selective aortic perfusion in particular the kidneys. Venous decompression using a femoral vein catheter enables a "two-way infusion system". Pre-transplant viability status of retrieved kidneys is determined by measuring pressure/resistance characteristics to the flow and biochemical markers for ischaemic injury. There were 90 NHBD renal transplants performed from 72 donors. Three renal transplants were carried out from three donors of ineffective in situ perfusion secondary to cannulation difficulties. Femoral cannulation was difficult as a result of extensive atherosclerosis of donor vessels. The comparison of allograft outcome from effective and ineffective in situ perfusion of donors showed high rate of primary nonfunction (PNF) from ineffective perfusion (chi-squared, P < 0.0001). The cases demonstrated poor outcome from ineffective perfusion related to the cannulation difficulties. Therefore a strict policy should be taken in cases where aortic cannulation and perfusion is inadequate, despite pretransplant assessment. In these circumstances, the primary warm ischaemia time should be extended to include this period of ineffective perfusion.
More Related Videos
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
09:10Normothermic Ex Situ Heart Perfusion in Working Mode: Assessment of Cardiac Function and Metabolism
Published on: January 12, 2019