Related Experiment Video
Updated: Aug 15, 2026

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
Published on: April 14, 2023
Effect of gamma radiation on amlodis and its potential for radiosterilization
Mustafa Polat1, Mustafa Korkmaz
1Physics Engineering Department, Hacettepe University, Beytepe, Ankara, Turkey. polat@hacettepe.edu.tr
Abstract:
In the present work, radiation sensitivity of amlodis (AML) and its active ingredient Amlodipin Besylate (AML-B) were separately investigated by electron spin resonance (ESR) spectroscopy using radiolytic products induced in these drugs. Irradiation in the dose range of 2.5-25kGy did not create any ESR resonance line in AML-B, but it create five characteristic ESR resonance lines associated with more than one radical species in the case of AML. This signal is attributed to the radical species created upon irradiation of inactive ingredients such as microcrystalline cellulose and sodium starch glycolate of AML. Five resonance lines were observed to be divided into three sub groups of different characteristic behaviors associable with three different radical species. Radical species responsible from observed ESR lines were unstable at room and above room temperatures, however, they conserved their identities over a storage period of 92 days. This permitted to discriminate irradiated AML from unirradiated one. A quadratic function was found to describe best the variations of the intensities of observed resonance lines with applied radiation dose. A model based on three tentative radical species with a pyranose ring formed by the rapture of CH bonds in positions 1 and 4 was proposed to explain the observed five lines experimental ESR spectra. AML was considered not providing the characteristic features of a good dosimetric material due to its low radiation yield and relatively fast decays of the created radical species, but very low radiation sensitivity of its active ingredient, namely AML-B makes AML a good candidate for radiosterilization.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Biological Effects of Radiation
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Isotopes and Radioisotopes
An isotope containing more...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:

