Related Experiment Video
Updated: Aug 15, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Automatic registration of PET and CT studies for clinical use in thoracic and abdominal conformal radiotherapy
G Rizzo1, I Castiglioni, R Arienti
1Institute of Molecular Bioimaging and Physiology (IBFM)-CNR, Milan, Italy. giovanna.rizzo@ibfm.cnr.it
Aim:
Implementation and validation of an automatic registration method based on mutual information (MI) for the integration of thoracic and abdominal positron emission tomography (PET)/computed tomography (CT) studies, with the purpose to facilitate in a clinical context the inclusion of PET metabolic information in conformal radiotherapy (RT).
Methods:
Registration was obtained by modeling a rigid spatial transformation between CT and PET transmission studies. The registration method was based on Normalized Mutual Information (NMI), by iteratively transforming the PET volume, until its optimal alignment to the CT study is achieved, in correspondence of the maximum of NMI. To avoid entrapment in local maxima and to improve convergence speed we introduced a multiresolution scheme. Accuracy of the proposed approach was investigated in experimental data, relative to phantom and patient studies, acquired in conditions similar to clinical situations.
Results:
In phantom studies the mean error in the 3D space is 3.6 mm (range 3-4 mm) in thoracic region and 3.2 mm (range 2.9-3.7 mm) in abdominal region, considerably less than PET spatial resolution. In patient studies the spatial mean error increases with respect to phantom studies (5.4 mm and 5.2 mm for thorax and abdomen, respectively) but remains comparable to the PET spatial resolution. The accuracy of spatial realignment was thus found adequate for the registration of PET/CT registration, if good patient repositioning was adopted.
Conclusions:
The proposed registration method, based on MI, was validated for the integration of PET/CT studies of patients candidate for thoracic and abdominal conformal RT. The method is automatic and provided with a user interface, thus suitable for clinical use.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography