Related Experiment Video
Updated: Aug 15, 2026

Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron (Oxy)Hydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
Field column study using zerovalent iron for mercury removal from contaminated groundwater
Christopher G Weisener1, K Scott Sale, David J A Smyth
1Department of Earth Sciences, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1. weisener@uwindsor.ca
Abstract:
Passive in situ remediation technologies, for example, permeable reactive barriers, PRBs, are an attractive and less expensive alternative compared to conventional pump and treat systems for groundwater remediation. Field column experiments were conducted to evaluate the removal of dissolved mercury from groundwater using zerovalent iron as the reactive media. Two column tests were conducted over a 6-week period, which simulated 2 and 10 years of groundwater flow through a potential full-scale treatment system. The influent groundwater pH was 7.8-9.5. The groundwater was reduced with an Eh, corrected to the standard hydrogen electrode, ranging from 0 to 120 mV over the trial period. Prior to treatment the total mercury concentration of the groundwater was approximately 40 microg L(-1). Effluent from the 10-year simulation contained approximately 0.5 microg/L of mercury during the first 3 weeks and increased to as much as 4 microg L(-1) by the end of the testing period. Effluent from the 2-year simulation was generally < 0.1 microg L(-1). Profile sampling of the 2-year simulation suggests that most of the mercury removal occurred in the initial 50% of the 20 cm column. Mineralogical studies, conducted using SEM/EDS and X-ray absorption spectroscopy (XAS), confirm the accumulation of mercury onto a zerovalent iron surface in this 20-cm zone. These analyses indicate that mercury accumulated as a mercury sulfide with a stoichiometery similar to those of cinnabar and metacinnabar (HgS).
Related Concept Videos
Microbial Leaching
Precipitation and Co-precipitation
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Extraction: Advanced Methods
Microbial Bioremediation of Uranium