Cardiac output measurement by pulse dye densitometry in cardiac surgery
W Baulig1, E O Bernhard, D Bettex
1Division of Cardiovascular Anaesthesia, University Hospital of Zürich, Rämistrasse 100, 8091 Zürich, Switzerland. werner.Baulig@usz.ch
Abstract:
Summary The aim of this study was to compare the accuracy of pulse dye densitometry with that of bolus thermodilution cardiac output measurement in patients before and after elective coronary artery bypass grafting. Twenty-eight patients were studied. Agreement between mean thermodilution and pulse dye densitometry cardiac output values was assessed by Bland-Altman analysis. Preoperative median [range] cardiac output was 3.87 [2.37-6.0] l.min(-1) by thermodilution, and 3.11 [1.7-5.45] l.min(-1) by pulse dye densitometry using indocyanine green 5 mg. Pulse dye densitometry underestimated cardiac output (mean bias - 0.42 l.min(-1)); the limits of agreement were +/- 1.91 l.min(-1), and mean error was 50.3%, indicating low precision. Preoperative median [range] cardiac output was 3.85 [2.2-6.0] l.min(-1) for bolus thermodilution cardiac output and 4.2 [2.0-7.2] l.min(-1) for pulse dye densitometry using indocyanine green 20 mg. Mean bias was + 0.566 l.min(-1), the limits of agreement were +/- 2.51 l.min(-1) and mean error was 60.9%. Postoperative cardiac output data were not analysed because pulse dye densitometry signals were low or absent in > 50% of the patients. We conclude that pulse dye densitometry using indocyanine green 5 mg or 20 mg is inaccurate in anaesthetised patients before coronary artery bypass surgery and cannot be used after surgery because of a high incidence of low pulse dye densitometry signal amplitudes.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Pulse
The pulse serves as a clinical indicator...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...