High-frequency ultrasonographic examination of the finger pulley system
Nathalie Boutry1, Marie Titécat, Xavier Demondion
1Department of Musculoskeletal Radiology, Hôpital Roger Salengro, Centre Hospitalier Régional Universitaire de Lille, Boulevard du Prof J. Leclercq, 59037 Lille Cedex, France. nboutry@chru-lille.fr
Objective:
The purpose of this study was to determine the ability of high-frequency ultrasonography to provide for direct evaluation of the annular and cruciform finger pulley system.
Methods:
In the first part of the work, a cadaveric study was performed to outline the normal anatomy of the annular and cruciform finger pulley system. Eighteen cadaveric hands were cut (n = 10) or dissected (n = 8). Two musculoskeletal radiologists retrospectively reviewed in consensus the photographs of anatomic sections and dissections. This cadaveric study gave the 2 readers the opportunity to learn the normal anatomy of the finger pulley system. In the second part of the work, the annular and cruciform finger pulley system of 20 hands of volunteers was evaluated by ultrasonography with a 17-MHz linear transducer. Images were retrospectively analyzed by means of consensus of the 2 radiologists with respect to the visibility of each finger pulley.
Results:
For annular (A) pulleys, high frequency ultrasonography showed A1, A2, A3, and A4 in 100%, 100%, 65%, and 100% of cases, respectively. For cruciform (C) pulleys, high-frequency ultrasonography showed only C1 in 45% of cases. Direct visualization of A5, C2, and C3 was not possible.
Conclusions:
High-frequency ultrasonography allows excellent depiction of finger pulleys except for annular pulley A5 and cruciform pulleys C2 and C3.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.