Related Experiment Video
Updated: Aug 15, 2026

Lateral-PLIF for Lumbar Spinal Arthrodesis: A Detailed Step-By-Step Surgical Technique
Published on: January 23, 2026
Results of four-corner arthrodesis using dorsal circular plate fixation
Corey B Kendall1, Timothy R Brown, S John Millon
1Greenville Hospital System and Hand Surgery Center, Greenville, SC 29605, USA.
Purpose:
Four-corner arthrodesis with scaphoid excision has been used to reduce pain and preserve functional range of motion for patients with radioscaphoid arthritis. Early results of 4-corner arthrodesis with scaphoid excision using dorsal circular plate fixation are compared with reported results in the literature.
Methods:
We reviewed retrospectively the first 18 four-corner arthrodeses performed with this system by 4 hand surgeons. Two patients had revision surgery for nonunions before the study that were considered failures. Eight patients returned for final radiographs, objective examination, and functional questionnaire. The average follow-up period was 20 months (range, 13-33 mo). These results were compared with reported results in the literature using alternate fixation methods.
Results:
Radiographic union was achieved in only 3 wrists. Range of motion was 46% that of the opposite normal wrist and grip strength compared with the opposite wrist was 56%. Five patients would have the procedure again and 6 of 8 have returned to their original employment.
Conclusions:
Four-corner arthrodesis with scaphoid excision using a circular internal fixation plate produced a high number of nonunions. Grip strength and range of motion results also were inferior to those reported in the literature.