Related Experiment Video
Updated: Jul 31, 2026

Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
Measurement of oxygen partial pressure in the mandibular bone using a polarographic fine needle probe
P Maurer1, L Meyer, A W Eckert
1Klinik und Poliklinik für Mund-Kiefer- und Plastische Gesichtschirurgie, Martin-Luther-Universität Halle-Wittenberg, Ernst-Grube-Strasse 40, D-06097 Halle, Germany. peter.maurer@medizin.uni.halle.de
Abstract:
In this study, the oxygen partial pressure in the cancellous bone substance of the mandible was measured for the first time with a polarographic fine needle probe. This has so far only been established in soft tissue. The aim was to prove and to test the feasibility in principle of this method of measurement in order to ascertain the normal values for the O2 partial pressure in healthy bone. These values were afterwards compared with the results of measurements in areas of different pathological bone conditions in order to assess the clinical suitability of the method for "mapping" during mandibular resection. Measurements of oxygen partial pressure were made in a total of 42 patients (16 women, 26 men). Of these, 12 patients with clinically normal bones served as a control group. Seventeen patients had osteoradionecrosis following radiation treatment, and 13 patients presented with chronic osteomyelitis of the mandible. All measurements were carried out with a polarographic fine needle probe applied to the cancellous bone substance. The statistical analysis included a comparison of the mean values of the oxygen partial pressures measured. No statistical correlation between oxygen partial pressure and pH and hemoglobin values could be detected. The average oxygen partial pressure in the healthy mandibular bone was 71.4 mmHg. In non-healthy bone, the value fell to an average of 30.6 mmHg (osteoradionecrosis 32.3 mmHg, chronic osteomyelitis of the mandibular bone 28.4 mmHg). Statistically, the differences in the group values ascertained were highly significant (P < 0.005). The data found show that this method can be successfully used to detect poorly perfused bone. The values are reproducible and reflect the clinical situation. In the long term, the method appears to be a suitable diagnostic tool for assessing the oxygen supply in bone in studying various clinical problems related to bone surgery.
More Related Videos
10:38Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose