Related Experiment Video
Updated: Aug 5, 2026

Measuring Influenza Neutralizing Antibody Responses to A(H3N2) Viruses in Human Sera by Microneutralization Assays Using MDCK-SIAT1 Cells
Published on: November 22, 2017
Measles immunity testing: comparison of two measles IgG ELISAs with plaque reduction neutralisation assay
B J Cohen1, R P Parry, D Doblas
1Virus Reference Department, Centre for Infections, Health Protection Agency, 61 Colindale Avenue, London NW9 5HT, UK. Bernard.cohen@hpa.org.uk
Abstract:
Two commercial IgG ELISAs, one based on recombinant nucleocapsid antigen and one based on cell culture grown native virus antigens, were evaluated for measles immunity testing by comparison with plaque reduction neutralisation test (PRNT). Qualitative results of the two ELISAs showed 92% agreement with those of PRNT. The sensitivity of the two ELISAs was 89.6%. False negative ELISA results were obtained in 10% of sera, mainly sera containing low levels of neutralising antibody. The specificity of both ELISAs was 100%. Measles IgG ELISAs perform adequately for immunity testing, correctly identifying seronegative individuals for vaccination.