Objectives:
Laryngeal dysfunction leading to incompetence and intractable aspiration can be a life-threatening problem. Laryngotracheal separation (LTS) can be used to prevent aspiration, but results in aphonia. The options for laryngeal speech following LTS are limited.
Methods:
We performed tracheoesophageal puncture (TEP) and insertion of a Blom-Singer valve in 3 patients in an attempt to restore their voice after LTS for chronic aspiration.
Results:
Two patients had intractable aspiration (5 and 14 years) after full-course radiotherapy for laryngeal cancer, and 1 patient had aspiration after a stroke. In the first patient TEP was done as a secondary procedure, and in the other 2 patients it was done at the time of the LTS. The TEP was successful in providing these patients with phonation ability after their LTS procedure. There was no morbidity from these procedures.
Conclusions:
Creation of a TEP after an LTS procedure is relatively simple and relatively safe, and allows for the control of aspiration while maintaining vocal function.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning II: Procedure
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: