Related Experiment Video
Updated: Aug 15, 2026

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
An evaluation of the initial distribution volume of glucose to assess plasma volume during a fluid challenge
Laurence van Tulder1, Burkhardt Michaeli, René Chioléro
1Surgical Intensive Care Unit, University Hospital, 1011 Lausanne, Switzerland.
Unlabelled:
Circulation blood volume can be estimated with the initial distribution volume of glucose (IDVG) method. In a prospective, observational study, we evaluated the effect of a fluid challenge on IDVG in individual patients. In 13 patients after cardiac surgery, IDVG was determined before and after the infusion of 7 mL/kg hydroxyethyl starch over 30 min. Eleven patients not requiring a fluid challenge served as control. IDVG was computed with a one-compartment exponential model, using plasma glucose concentrations at baseline and 3, 4, 5, 6, and 7 min after 5 g of glucose IV bolus. IDVG was repeated 3 times in the control group. IDVG did not change after a fluid challenge (85 +/- 14 versus 93 +/- 14 mL/kg, P = 0.08), and the power of the comparison was 0.25 for a P value of 0.05. The regression coefficient of the exponential fit of glucose versus time was 0.96 +/- 0.03 before, and 0.95 +/- 0.04 after starch infusion (not significant). In the control group, IDVG was 90 +/- 18 mL/kg, and the average individual coefficient of variation was 0.15 +/- 0.08. IDVG seems inadequate to assess individual response to fluid therapy. This limitation may be related to the weak reproducibility of IDVG.
Implications:
The initial distribution volume of glucose (IDVG) is supposed to reflect effective circulating blood volume. We assessed the sensitivity of this method to a fluid challenge in patients receiving a fluid challenge, and the reproducibility in otherwise stable patients. IDVG was not sensitive to a fluid challenge, and reproducibility was poor. Thus, clinical usefulness of IDVG seems limited.
Related Concept Videos
Drug Distribution: Volume of Distribution
Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution

