Related Experiment Video
Updated: Aug 15, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Phasic coronary blood flow pattern during a continuous flow left ventricular assist support
Yoshio Ootaki1, Keiji Kamohara, Masatoshi Akiyama
1Department of Biomedical Engineering, Lerner Research Institute, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA.
Objective:
Continuous flow left ventricular assist devices (LVADs) have been introduced and tested as a bridge to heart transplantation, bridge to recovery, and destination therapy, and several studies have been conducted to assess the physiologic effects of continuous flow LVADs. However, the effect of reduced pulsatility on the phasic coronary blood flow pattern is unknown. The aim of this study was to investigate the phasic coronary blood flow patterns during continuous flow LVAD support.
Methods:
Phasic coronary blood flow patterns and hemodynamic data were analyzed using three flow probes placed around the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and the right coronary artery (RCA) in 16 pigs before and after initiating the LVAD support with or without creating LAD stenosis.
Results:
The total coronary blood flow (TCBF, 112.8+/-31.4 mL/min) gradually decreased when the continuous flow LVAD support increased to 2.0 L/min (110.7+/-29.0 mL/min, P = 0.571), 2.5 L/min (103.7+/-26.1 mL/min, P = 0.079), and 3.0 L/min (101.5+/-27.2 mL/min, P = 0.027) because of decreases in LAD flow and LCX flow. LVAD support caused decrease in systolic and peak systolic LAD flow, LCX flow, and RCA flow, whereas diastolic RCA flow increased. In the presence of LAD stenosis, the TCBF (97.7+/-36.1 mL/min) decreased when the continuous flow LVAD support increased to 2.0 L/min (83.9+/-22.1 mL/min, P = 0.029), 2.5 L/min (83.2+/-25.2 mL/min, P = 0.012), and 3.0 L/min (87.6+/-23.4 mL/min, P = 0.005) because of decreases in LCX flow.
Conclusion:
Use of a continuous flow LVAD decreased TCBF, LAD flow, and LCX flow secondary to reduced systolic LAD flow and LCX flow, and decreased TCBF and LCX flow in the presence of LAD stenosis. These findings are potentially relevant to understanding the physiology of myocardial blood perfusion during continuous flow LVAD support especially in patients with coronary artery disease.
More Related Videos
Related Concept Videos
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...