Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Radiation-reducing planning of cardiac catheterisation
E Kuon1, J B Dahm, D M Robinson
1Department of Cardiology, Klinik Fränkische Schweiz, Feuersteinstrasse 2, 91320, Ebermannstadt, Germany. Eberhard.Kuon@klinik-fraenkische-schweiz.de
Abstract:
Any radiation exposition for medical purposes should be kept as low as is reasonably achievable. Mean patient radiation exposure of diagnostic cardiac catheterisation is high (16-106 Gy x cm2) and for this reason the International Commission on Radiological Protection (ICRP) recommends credentialing radiation protection training programmes. Twenty cardiologists each documented various dose parameters of 10 cardiac catheterisations, before and after a 90-minute mini-course of the ELICIT study group ("Encourage to Less Irradiating Cardiologic Interventional Techniques"), and could achieve a reduction of the mean dose-area product by 15.9+/-9.0 Gy x cm2, equivalent to 47%. The presented radiation-reducing planning of invasive cardiac catheterisation for this reason is the first one validated in clinical routine and consists of 6 standard runs--one for the left ventricle, 3 and 2 for the left (LCA) and right coronary artery (RCA), respectively--depending on anatomy and findings supplemented by 1...4 special projections. The caudal posteroanterior (PA) view documents the left coronary main stem, proximal and distal left anterior descending artery (LAD), and proximal and mid circumflex segments. The cranial PA view however is suitable for the left coronary orifice, circumflex periphery, LAD, all diagonal bifurcations, and collateral pathways towards the RCA. LCA standard angiography is completed by lateral 90 degrees/0 degrees left anterior oblique (LAO) angulation. The 60 degrees/0 degrees LAO angulation visualises the right posterolateral artery (RPL) and the RCA to its bifurcation. The more proximal one finds the bifurcation, the more the second standard cranial PA view for RCA should vary towards the cranial right anterior oblique (RAO) and finally 30 degrees/0 degrees RAO view. The efficiency of these less-irradiating angulations are improved by radiation-reducing techniques as follows: restriction to essential radiographic frames and runs, consistent collimation to the region of interest--particularly during coronary intubation--, adequate instead of best possible image quality, short skin-to-image-intensifier distance, inspiration during radiography, preference for projections that rotate out the spine, optimisation of fluoroscopy time, well-experienced and well-rested interventionists.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization