Related Experiment Video
Updated: Aug 15, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Automated assessment of blood pressure using BpTRU compared with assessments by a trained technician and a clinic
Norm R C Campbell1, Heather E Conradson, Jian Kang
1Department of Medicine, Faculty of Medicine, The University of Calgary, Calgary, Alberta, Canada. ncampbel@ucalgary.ca
Objective:
To determine the accuracy and reproducibility of a new automated blood pressure manometer (BpTRU) relative to auscultatory blood pressure assessed by a research nurse and to that assessed by a clinic nurse.
Methods:
Firefighters in a cohort study had blood pressure assessed on up to five occasions with BpTRU and by a trained research technician. Patients in an internal medicine clinic had blood pressure assessed by the clinic nurse and by BpTRU. The absolute values of blood pressure, reproducibility and effect on hypertension classification were compared with the different methods.
Results:
The research technician readings were higher than the BpTRU readings at visit 1 (3.0/2.7 mmHg, P<0.0001) but the readings converged by visits 4-5 because of a greater reduction in the research nurse readings. The BpTRU readings had similar reproducibility and classification of hypertension as the research technician but did not exhibit terminal digit preference while the research technician readings did. The BpTRU had substantially lower readings (8/7 mmHg) and fewer hypertensive readings than those of the nurse in the internal medicine clinic.
Conclusions:
This preliminary study found that the BpTRU had desirable characteristics that suggest that it would be a suitable replacement for auscultatory assessment of blood pressure in clinical practice. A large confirmatory study performed in a usual clinic setting is required.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement