Related Experiment Video
Updated: Aug 15, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
99mTc ovalbumin labelled eggs for gastric emptying scintigraphy: in-vitro comparison of solid food markers
Frédérique Blanc1, Pierre Y Salaun, Olivier Couturier
1Nuclear Medicine Department, University Hospital, Brest, France.
Background:
The reliability of solid phase gastric emptying measurements by scintigraphy requires a marker that remains within the solid component of the test meal, and which is not degraded by the gastric juice throughout the scintigraphic procedure. In Europe, foods are most often labelled with 99mTc rhenium sulfide macrocolloid (RSMC) but this solid phase marker was withdrawn from the market in January 2004.
Objective:
To test other potential solid phase markers and to compare them to the reference marker RSMC. These markers were rhenium sulfide nanocolloid (RSNC), tin fluoride colloid (TFC), phytates and two albumins (Alb and AlbC). All were radiolabelled with 99mTc.
Methods:
After quality control, each 99mTc marker was incorporated into the albumin of one egg. Then, egg white and yolk were mixed together, and a well-cooked omelette was prepared. Aliquots of the omelette were incubated with an acidic solution of pepsin at 37 degrees C which mimicked gastric juice. Unbound radioactivity in the supernatant fraction was measured at various times up to 3 h.
Results:
The radiochemical purity was > 95% for all radiopharmaceuticals. During the in-vitro incubation, the percentage of 99mTc labelled colloids released from the omelette increased continuously: after 3 h, 5% for TFC and RSMC, 8% for phytates, and > 9% for the two albumins and RSNC.
Conclusion:
Considering quality controls and release of 99mTc during in-vitro incubation of the omelette, TFC showed the same behaviour as the reference marker RSMC. Thus, TFC seems to be the best candidate to replace RSMC for the radiolabelling of the solid phase of the gastric emptying test meal.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...