Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Determination of total arsenic content in water by atomic absorption spectroscopy (AAS) using vapour generation
Jai Raj Behari1, Rajiv Prakash
1Analytical Chemistry Department, Industrial Toxicology Research Centre, P.O. Box 80, M.G. Marg, Lucknow 226001, UP, India.
Abstract:
Analysis of arsenic in water is important in view of contamination of ground water with arsenic in some parts of the world including West Bengal in India and neighboring country Bangladesh. WHO has fixed the threshold for arsenic in drinking water to 10ppb (microg/l) level, hence the methodology for determination of arsenic is required to be sensitive at ppb level. Atomic absorption spectrophotometry with vapour generation assembly (AAS-VGA) is well known technique for the trace analysis of arsenic. However, total arsenic analysis [As(III)+As(V)] is very crucial and it requires reduction of As(V) to As(III) for correct analysis. As(III) is reduced to AsH3 vapours and finally to free As atoms, which are responsible for absorption signal in AAS. To accomplish this the vapour generation assembly attached to AAS has acid channel filled with 10 M HCl and the reduction channel with sodium borohydride. Further sample can be reduced either before aspiration for analysis, using potassium iodide (KI) or the sample can be introduced in the instrument directly and KI can be added in the reduction channel along with the sodium borohydride. The present work shows that samples prepared in 3 M HCl can be reduced with KI for 30 min before introduction in the instrument. Alternatively samples can be prepared in 6 M HCl and directly aspirated in AAS using KI in VGA reduction channel. The latter methodology is more useful when the sample size is large and time cycle is difficult to maintain. It is observed that the acid concentration of the sample in both the situations plays an important role. Further reduction in acid concentration and analysis time is achieved for the arsenic analysis by using modified method. Analysis in both the methods is sensitive at ppb level.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...