Related Experiment Video
Updated: Aug 15, 2026

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Hemodynamic assessment in a pregnant and peripartum patient
Shigeki Fujitani1, Marie R Baldisseri
1UCLA-VA Greater Los Angeles Program, Infectious Disease Section 111F, Los Angeles, CA, USA.
Pathophysiology:
Critical care in obstetrics has many similarities in pathophysiology to the care of nonpregnant women. However, changes in the physiology of pregnant woman necessary to maintain homeostasis for both mother and fetus, especially during critical illness, result in complex pathophysiology. Understanding the normal physiologic changes during pregnancy, intrapartum, and postpartum is the key to managing critically ill obstetric patients with underlying medical diseases and pregnancy-related complications.
Hemodynamic Monitoring:
When the pathophysiology of critically ill obstetric patients cannot be explained by noninvasive hemodynamic monitoring and the patient fails to respond to conservative medical management, invasive hemodynamic monitoring may be helpful in guiding management. Most important, the proper interpretation of hemodynamic data is predicated on knowledge of normal values during pregnancy and immediately postpartum. Invasive hemodynamic monitoring with pulmonary artery catherization has been used in the obstetric population, particularly in patients with severe preeclampsia associated with pulmonary edema and renal failure.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Measurement of Blood Pressure