Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
[Is masked hypertension an artefact due to the blood pressure measurement method and threshold effects?]
P Poncelet1, P Clerson, J Ribstein
1Polyclinique de Hénin-Beaumont. pponcelet@ahnac.com
Unlabelled:
From results of office and home measurements of blood pressure (BP), patients can be classified as "hypertensive (HT)", "normotensive (NT)", "office hypertensive (OH)" or "masked hypertensive (MH)" by crossing the classifications obtained from each method. It seems that 9 to 20% of patients could be MH with a prognosis close to HT (SHEAF study).
Objectives:
To test the hypothesis that at least one part of the prevalence of MH would be an artefact due to the difference between the methods of measurements (shygmomanometer vs semi-automatic device) and/or due to different definitions of office hypertension (OHT). To determine the impact of different definitions of OHT on the prevalence of MH.
Methods:
During the course of a phase IV study, BP was measured with the same semi-automatic device (OMRON 705CP) both at doctor's office (3 measurements at 1-minute intervals) and at home, by the patient himself (3 measurements in the morning and in the evening at 1-minute intervals over the 7 days before the visit). Following definitions were used: Office HT: SBP > or =140 mmHg, DBP > or =90 mmHg, SBP > or =140 mmHg or DBP > or =90 mmHg; Home HT: SBP > or =135 mmHg, DBP> or =85 mmHg, SBP > or =135 mmHg or DBP > or =85 mmHg. Another definition of office HT was used SBP > or =135 mmHg, DBP > or =85 mmHg SBP > or =135 mmHg or DBP > or =85 mmHg.
Results:
575 patients were analysed. Results from the two methods of measurements are closed but significantly different (difference for SBP: 3.2 +/- 16.5 mmHg; p < 0.0001; difference for DBP: 1.4 +/- 10.3 mmHg; p = 0.002)
Related Concept Videos
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)