[Use of home blood pressure devices in France in 2004]
J J Mourad1, D Herpin, N Postel-Vinay
1Comité français de lutte contre l'hypertension artérielle, service d'endocrinologie-métabolisme, hôpital La Pitié-Salpêtrière, Paris.
Objective:
To estimate the number of devices for home blood pressure measurements in the French population in 2004 and to evaluate the use of these apparatus.
Methods:
The French League Against Hypertension Survey 2004 (FLAHS-2004) was performed cross-sectionally on 3707 subjects, part of a sample of 5476 subjects selected as being representative of the French metropolitan population for age (35 years and above), gender, socioeconomic status, and place of living. Subjects who declare to take an antihypertensive medication were classified as treated hypertensive patients. A questionnaire evaluating the condition of use of HBP device was given.
Results:
In 2004, 24% of the French population above the age of 35 years was treated for hypertension, corresponding to an estimate of 7.5 million of subjects. 25% of treated hypertensives and 12% of untreated subjects had a tensiometer. A total of 4 millions of BP devices are owned in the general population with 43% by treated hypertensive patients. 67% of BP devices are wrist cuff. Medical doctors recommended home blood pressure monitoring in only 12% of subjects.
Conclusion:
In 2004, the number of subjects treated for hypertension is 1/4 of the general population over the age of 35 years in France. In this group of subjects, 1/4 possessed a tensiometer but in only 10% medical doctor recommended the use of home blood pressure monitoring.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.