Related Experiment Video
Updated: Aug 15, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Evaluation of the sensitivity of miniaturized liquid chromatography-electrospray ionization-mass spectrometry for
Martijn Kranendijk1, Joop C M Waterval, Govert W Somsen
1Department of Pharmaceutics, N.V. Organon (Akzo Nobel), Oss, The Netherlands. martijn.kranendijk@organon.com
Abstract:
LC-ESI-MS is applied frequently in pharmaceutical analysis. The sample amount is generally not restricted, however with LC-ESI-MS, a lack of sensitivity may still be observed with standard-bore LC columns in isocratic mode. Therefore, it was investigated whether increased sensitivity could be achieved by using miniaturized LC-ESI-MS. Seven columns ranging from 0.1 to 4.6 mm ID were tested using several instrument setups. For proper comparison, a sensitivity gain factor (SGF) was introduced. The SGF expresses the extra sensitivity that may be obtained on top of the normal increase of peak concentration, which can be expected when the column ID is reduced. Desogestrel, mirtazapine, and sugammadex sodium were used as test compounds. For desogestrel and sugammadex sodium, the SGF increased up to a factor of 5-13 when the column ID was reduced, indicating enhanced ionization efficiencies at lower flow rates. Optimum sensitivity was found for the 0.3 mm column coupled in combination with a microinjection valve and a dedicated low flow rate interface. For mirtazapine, no increase of SGF was observed when the column ID was decreased. Apparently, the ionization efficiency of this compound is not affected by the flow rate and the spray quality.
More Related Videos
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...