Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Reliability of carotid doppler performed in a dedicated stroke prevention clinic
1Division of Neurology, The Al Owen and Family Stroke Prevention Clinic, University of Alberta, Edmonton, Alberta, Canada.
Introduction:
Doppler ultrasound (DUS) is used as a screening tool to assess internal carotid artery (ICA) disease. Recent reports suggest that the DUS may be inaccurate in over 28% of patients. We sought to evaluate the accuracy of DUS, when performed in a dedicated stroke prevention clinic (SPC).
Methods:
We retrospectively reviewed the charts of patients who had a DUS performed in our SPC, followed by conventional cerebral angiography. Three groups of patients were defined. Group 1 had DUS measured ICA stenosis of >50%; Group II had a DUS measured ICA stenosis of <50%; Group III had complete ICA occlusion on DUS.
Results:
Sixty-seven patients (69 arteries) were included in the study. There were 45 patients in Group I and based on the findings of cerebral angiography, carotid endarterectomy was considered inappropriate in only one patient--a misclassification rate of 2.2% (95% CI: 0 - 6.5%). Group II consisted of 19 patients and on cerebral angiography, none of these patients had a stenosis of >50%--a misclassification rate of 0%. Group III consisted of five patients in whom DUS showed complete ICA occlusion. The angiogram confirmed the occlusion in all five patients--a misclassification rate of 0%. Overall, misclassification rate was 1.45% (95% CI: 0 - 4.3%).
Conclusions:
Doppler ultrasound when performed in a stroke prevention clinic (SPC), has a high accuracy in measuring ICA stenosis of >50%. Doppler ultrasound is reliable in detecting complete ICA occlusion and finally DUS is a reliable screening tool to rule out clinically significant ICA stenosis.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: