Related Experiment Video
Updated: Aug 15, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Measurement of the pressure applied during motion palpation and reliability for cervical spine rotation
Justin Marcotte1, Martin C Normand, Pierre Black
1Département de Chiropratique, Université du Québec à Trois-Rivières, Quebec, Canada. justin_marcotte@videotron.ca
Objective:
To measure the pressure applied during motion palpation for cervical spine rotation and to verify its effect on reliability when the kinematics of the test are standardized.
Methods:
The pressure of palpation used during the test of cervical spine rotation was measured by means of flexible and extra-fine pressure sensors linked to an electronic interface. Seven pressure measurements (left rotation from C1 to C7) for each of 24 examiners were taken. In addition, the examiners were asked to detect the presence of intervertebral fixation while palpating.
Results:
Pressure of palpation varied from 4.0 to 41.0 N/cm2 among the examiners. Standardization of the kinematics of the test establishes a strong reliability of identifying a fixation (kappa varying from 0.701 to 0.748).
Conclusions:
The pressure applied during motion palpation for cervical spine rotation is light to moderate. It can vary tenfold (4-41 N/cm2) and remain reliable for identifying a fixation as long as the kinematics of the test are standardized.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Abdomen III: Palpation
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
