Should electronic faucets be used in intensive care and hematology units?
Jacques Merrer1, Emmanuelle Girou, David Ducellier
1Unité d'Hygiène et de Lutte contre les Infections Nosocomiales, Centre Hospitalier de Poissy/Saint Germain-en-Laye, 10 Rue du Champ Gaillard, 78300, Poissy, France, jmerrer@chi-poissy-st-germain.fr
Objective:
To compare bacterial contamination associated with electronic faucets and manual faucets in wards admitting patients highly susceptible to infection.
Design:
Water samples from electronic faucets and manual faucets were taken according to the French recommendations on water surveillance in healthcare settings.
Setting:
Hematology and intensive care units (ICUs) of a 900-bed university hospital and a 500-bed general hospital.
Measurements And Results:
Overall 227 water samples were collected, 92 from electronic faucets and 135 from manual faucets. Thirty-six (39%) of the water samples from electronic faucets and 2 (1%) from manual faucets yielded pathogenic bacteria. In hematology wards 17 (30%) samples from electronic faucets and 2 (2%) from manual faucets were contaminated. In ICUs 19 (53%) samples from electronic faucets and none of 48 from manual faucets were contaminated. All samples were contaminated with various strains of Pseudomonas aeruginosa (8 to >100 CFU/100 ml). Despite hyperchlorination the electronic faucets remained contaminated. Replacing the contaminated electronic faucets by manual faucets led to a complete and sustained elimination of bacterial contamination. Contamination was not associated with a particular brand of electronic faucets.
Conclusions:
Our findings demonstrate that electronic faucets are significantly more frequently contaminated than manual faucets and could be a major reservoir for P. aeruginosa. Wards admitting patients highly susceptible to infection and using electronic faucets should be aware of this potential threat. Moreover, units already equipped with these devices, should check water quality periodically.
Related Concept Videos
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated.
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...