Related Experiment Video
Updated: Aug 15, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Airway narrowing measured by spirometry and impulse oscillometry following room temperature and cold temperature
Tina M Evans1, Kenneth W Rundell, Kenneth C Beck
1Marywood University, 2300 Adams Ave, Scranton, PA 18509, USA.
Study Objective:
The efficacy of using impulse oscillometry (IOS) as an indirect measure of airflow obstruction compared to spirometry after exercise challenges in the evaluation of exercise-induced bronchoconstriction (EIB) has not been fully appreciated. The objective was to compare airway responses following room temperature and cold temperature exercise challenges, and to compare whether IOS variables relate to spirometry variables.
Design:
Spirometry and IOS were performed at baseline and for 20 min after challenge at 5-min intervals.
Setting:
Two 6-min exercise challenges, inhaling either room temperature (22.0 degrees C) or cold temperature (- 1 degrees C) dry medical-grade bottled air. At least 48 h was observed between these randomly assigned challenges.
Participants:
Twenty-two physically active individuals (12 women and 10 men) with probable EIB.
Interventions:
Subjects performed 6 min of stationary cycle ergometry while breathing either cold or room temperature medical-grade dry bottled air. Subjects were instructed to exercise at the highest intensity sustainable for the duration of the challenge. Heart rate and kilojoules of work performed were documented to verify exercise intensity.
Measurements And Results:
Strong correlations were observed within testing modalities for post-room temperature and post-cold temperature exercise spirometry and IOS values. Spirometry revealed no differences in postexercise peak falls in lung function between conditions; however, IOS identified significant differences in respiratory resistance (p < 0.05), with room temperature-inspired air being more potent than cold temperature-inspired air.
Conclusions:
Correlations were found between spirometric and IOS measures of change in airway function for both exercise challenges, indicating close equivalency of the methods. The challenges appeared to elicit the EIB response by a similar mechanism of water loss, and cold temperature did not have an additive effect. IOS detected a difference in degree of response between the temperatures, whereas spirometry indicated no difference, suggesting that IOS is a more sensitive measure of change in airway function.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...