Related Experiment Video
Updated: Aug 15, 2026

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Ionic liquid matrix-induced metastable decay of peptides and oligonucleotides and stabilization of phospholipids in
Jeffrey J Jones1, S Mariccor A B Batoy, Charles L Wilkins
1Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, 72701, USA.
Room-temperature ionic liquid matrices (ILMs) have recently been investigated for use in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and proven to be advantageous. Literature accounts of ILM performance for biological samples document increased sensitivity and ionization efficiency. These claims have been investigated here, and are supported for MALDI TOF applications to peptides, oligonucleotides, and phospholipids. Peptides and oligonucleotides however, do not behave in the same way when ILMs are used for MALDI FTMS. As reported here, with 3 tesla MALDI FTMS peptides and oligonucleotides fragment readily. These observations contrast with those found for MALDI time-of-flight mass spectrometry. Fragmentation is apparently slower than the time required to accelerate ions in a MALDI TOF mass spectrometer, but is readily observed by MALDI FTMS. Therefore, fragmentation of these molecules must occur on a relatively slow time scale. As trapping time is extended, increased fragmentation of peptides and oligonucleotides is seen. However, phospholipids do not fragment extensively. Furthermore, use of traditional solid matrices causes significant fragmentation for this category of compound but is suppressed by use of ILMs.
Room-temperature ionic liquid matrices (ILMs) have recently been investigated for use in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and proven to be advantageous. Literature accounts of ILM performance for biological samples document increased sensitivity and ionization efficiency. These claims have been investigated here, and are supported for MALDI TOF applications to peptides, oligonucleotides, and phospholipids. Peptides and oligonucleotides however, do not behave in the same way when ILMs are used for MALDI FTMS. As reported here, with 3 tesla MALDI FTMS peptides and oligonucleotides fragment readily. These observations contrast with those found for MALDI time-of-flight mass spectrometry. Fragmentation is apparently slower than the time required to accelerate ions in a MALDI TOF mass spectrometer, but is readily observed by MALDI FTMS. Therefore, fragmentation of these molecules must occur on a relatively slow time scale. As trapping time is extended, increased fragmentation of peptides and oligonucleotides is seen. However, phospholipids do not fragment extensively. Furthermore, use of traditional solid matrices causes significant fragmentation for this category of compound but is suppressed by use of ILMs.
More Related Videos
08:16Optimal Preparation of Formalin Fixed Samples for Peptide Based Matrix Assisted Laser Desorption/Ionization Mass Spectrometry Imaging Workflows
Published on: January 16, 2018
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...