Related Experiment Video
Updated: Aug 15, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Female breast radiation exposure during CT pulmonary angiography
Mark S Parker1, Ferdinand K Hui, Marc A Camacho
1Department of Radiology, Thoracic Imaging, Medical College of Virginia Hospitals, Virginia Commonwealth University Health System, 1250 E Marshall St., Main Bldg., 3rd Fl., PO Box 980615, Richmond, VA 23298-0615, USA. msparker@mail1.vcu.edu
Objective:
The objective of our study was to estimate the effective radiation dose to the female breast during CT pulmonary angiography compared with other routine diagnostic imaging techniques.
Materials And Methods:
We retrospectively reviewed the demographic data of patients who underwent CT pulmonary angiography between May 2000 and December 2002, the diagnostic yield of those studies, and the estimated effective radiation dose to the breast incurred during CT. The estimated effective radiation dose was calculated using the ImPACT CT (Impact Performance Assessment of CT) dosimetry calculator and the CT dose index (CTDI) and was compared with the average glandular dose for two-view screening mammography.
Results:
During the study period, 1,325 CT pulmonary angiograms were obtained. Sixty percent (797) of the scans were obtained on female patients. The mean age of scanned females was 52.5 years (range, 15-93 years). Of the studies performed in females, 401 (50.31%) were negative, 151 (18.95%) were nondiagnostic, and 245 (30.74%) were positive for pulmonary thromboembolism. The calculated effective minimum dose to the breast of an average 60-kg woman during CT was 2.0 rad (20 mGy) per breast compared with an average glandular dose of 0.300 rad (3 mGy) for standard two-view screening mammography.
Conclusion:
CT pulmonary angiography delivers a minimum radiation dose of 2.0 rad (20 mGy) to the breasts of an average-sized woman. This greatly exceeds the American College of Radiology recommendation of < or = 0.300 rad (3 mGy) or less for standard two-view mammography. The potential latent carcinogenic effects of such radiation exposure at this time remain unknown. We encourage the judicious use of CT pulmonary angiography and lower doses and nonionizing radiation alternatives when appropriate.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...