Related Experiment Video
Updated: Aug 15, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Investigation of arsenic speciation on drinking water treatment media utilizing automated sequential continuous flow
Patricia A Creed1, Carol A Schwegel, John T Creed
1US EPA, NERL, Microbiological and Chemical Exposure Assessment Research Division, Cincinnati, OH 45268, USA. Creed.Jack@epa.gov
Abstract:
Three treatment media, used for the removal of arsenic from drinking water, were sequentially extracted using 10 mM MgCl2(pH 8), 10 mM NaH2PO4(pH 7) followed by 10 mM (NH4)2C2O4(pH 3). The media were extracted using an on-line automated continuous extraction system which allowed the arsenic in each of the extraction fluids to be speciated on-line using IC-ICP-MS. The 10 mM MgCl2 preferentially extracted As(III) from each of the media. The percentage of the arsenic extracted by the MgCl2, relative to a HNO3/H2O2 digestion of the media, ranged from 0.1-2.3% for the three solids. The next sequential extraction fluid, 10 mM NaH2PO4, extracted some of the residual As(III) remaining on each of the media but the predominant species extracted was As(V). The 10 mM NaH2PO4 extracted 15.3 to 42.8% of the total arsenic relative to a total digested concentration for each of the media. The As(III) and As(V) stability studies conducted in these two extraction fluids indicated that conversion between As(III) and As(V) was not significant for the short extraction fluid sample contact time associated with the on-line continuous flow extraction cell. Finally, the 10 mM (NH4)2C2O4 extraction fluid was utilized in an off-line analysis mode because the Fe and As concentrations extracted from the media were not compatible with direct ICP-MS detection. The (NH4)2C2O4 extracted 2.9-29% As(III) for all three media and caused an oxidation of As(III) to As(V) during the extraction period for one of the three media. The sum of the arsenic from each of the three extraction fluids represented 92%, 44% and 53% of the available total arsenic for the three media, respectively. The speciation results for each media were obtained by adding all the speciation results from all three extraction fluids together and the resulting distribution of As(III)/As(V) compared well with the speciation results obtained via XANES.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Ion-Exchange Chromatography
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Precipitation and Co-precipitation

