Multivariate optimization approach for chiral resolution of drugs using human serum albumin in affinity
Maria A Martinez-Gomez1, Rosa M Villanueva-Camañas, Salvador Sagrado
1University of Valencia, Vicente Andrés Estellés, Burjasot, Spain.
Abstract:
The enantiomeric resolution of chiral compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer, protein and compound solutions) and protein solution plug length. In this paper multivariate optimization approaches for chiral separation of four basic drugs (alprenolol, oxprenolol, promethazine and propranolol) using HSA as chiral selector in AEKC-partial filling technique are studied. The experimental conditions to achieve maximum resolution are optimized using the Box-Behnken experimental design. Partial least squares and pareto charts are used to analyse the main effects on the resolution. The experimental resolutions observed for all compounds studied in optimum conditions agree with the estimated values based on response surface models. The results obtained show that the range of experimental conditions that provided enantioresolution narrows as hydrophobicity of analytes decreases. This fact can be explained by assuming that hydrophobicity controls the interaction of basic compounds with HSA.
More Related Videos
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion-Exchange Chromatography
Affinity Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Elution Process