Abstract:
Traditional auscultation performed by the general practitioner remains problematic and often gives significant results only in a late stage of heart valve disease. Valve stenoses and insufficiencies are nowadays diagnosed with accurate but expensive ultrasonic devices. This study aimed to develop a new heart sound analysis method for diagnosing aortic valve stenoses (AVS) based on a wavelet and correlation technique approach. Heart sounds recorded from 373 patients (107 AVS patients, 61 healthy controls (REF) and 205 patients with other valve diseases (OVD)) with an electronic stethoscope were wavelet filtered, and envelopes were calculated. Three correlations on the basis of these envelopes were performed: within the AVS group, between the groups AVS and REF and between the groups AVS and OVD, resulting in the mean correlation coefficients rAVS, rAVSv.REF and rAVSv.OVD. These results showed that rAVS (0.783 +/- 0.097) is significantly higher (p < 0.0001) than rAVSv.REF (0.590 +/- 0.056) and rAVSv.OVD (0.516 +/- 0.056), leading to a highly significant discrimination between the groups. The wavelet and correlation-based heart sound analysis system should be useful to general practitioners for low-cost, easy-to-use automatic diagnosis of aortic valve stenoses.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.