Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability
N K Kristiansen1, J Fleischer, M S Jensen
1Department of Electronics & Information Technology, University College of Aarhus, Denmark.
Abstract:
Heart rate variability (HRV) analysis from 10s ECGs has been shown to be reliable. However, the short examination time warrants a user-friendly system that can be used for ad-hoc examinations without normal preparation, unlike ECG. A handheld device has been developed that can measure ultra-short HRV from impedance plethysmographic recordings of the pulse wave in distal superficial arteries. The prototype device was made user-friendly through a compact, pen-like design and the use of integrated metal electrodes that were especially designed for dry operation. The main signal processing was performed by a digital signal processor, where the discrete heart beats were detected using a correlation algorithm that could adapt to individual pulse wave shapes to account for biological variation. The novel device was evaluated in 20 mainly young volunteers, using 10 s time-correlated ECG recordings as the reference method. Agreement between the two methods in measuring heart rate and root mean square of successive differences in the heart beat interval (RMSSD) was analysed using correlation coefficients (Pearson's R2), mean differences with 95% confidence intervals and 95% limits of agreement, and Bland-Altman plots. The correlation between the two methods was R2 = 1.00 and R2 = 0.99 when heart rate and RMSSD were measured, respectively. The Bland-Altman plots showed suitable agreement between the novel device and standard 10 s ECGs, which was substantiated by 95% limits of agreement of the difference of +/- 0.1 beats min(-1) and approximately +/- 10 ms for heart rate and RMSSD, respectively. Therefore the evaluation showed no significant systematic error of the novel device compared with ECG.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Dysrhythmias V: Evaluating Dysrhythmias
Special considerations while measuring pulse
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...