Related Experiment Video
Updated: Aug 15, 2026

Single Cell Analysis Of Transcriptionally Active Alleles By Single Molecule FISH
Published on: September 20, 2020
Position of the fluorescent label is a crucial factor determining signal intensity in microarray hybridizations
Lei Zhang1, Thomas Hurek, Barbara Reinhold-Hurek
1Laboratory of General Microbiology, Center of Applied Gene Sensoric (CAG), University of Bremen, PO Box 33 04 40, D-28334 Bremen, Germany.
Abstract:
A key issue in applications of short oligonucleotide-based microarrays is how to design specific probes with high sensitivity. Some details of the factors affecting microarray hybridization remain unclear, hampering a reliable quantification of target nucleic acids. We have evaluated the effect of the position of the fluorescent label [position of label (POL)] relative to the probe-target duplex on the signal output of oligonucleotide microarrays. End-labelled single-stranded DNA targets of different lengths were used for hybridization with perfect-match oligonucleotide probe sets targeting different positions of the same molecule. Hybridization results illustrated that probes targeting the labelled terminus of the target showed significantly higher signals than probes targeting other regions. This effect was independent of the target gene, the fluorophore and the slide surface chemistry. Comparison of microarray signal patterns of fluorescently end-labelled, fluorescently internally random-labelled and radioactively end-labelled target-DNAs with the same set of oligonucleotide probes identified POL as a critical factor affecting signal intensity rather than binding efficiency. Our observations define a novel determinant for large differences of signal intensities. Application of the POL effect may contribute to better probe design and data interpretation in microarray applications.
More Related Videos
07:51Method for Labeling Transcripts in Individual Escherichia coli Cells for Single-molecule Fluorescence In Situ Hybridization Experiments
Published on: December 21, 2017
10:01Probing mRNA Kinetics in Space and Time in Escherichia coli using Two-Color Single-Molecule Fluorescence In Situ Hybridization
Published on: July 30, 2020
Related Concept Videos
FISH - Fluorescent In-situ Hybridization
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
DNA Microarrays
In-situ Hybridization
Types of probes and labels
A probe is a complementary strand of DNA or RNA that binds to corresponding nucleotide sequences in a cell. Many...