Related Experiment Video
Updated: Aug 1, 2026

Murine Lymphocyte Labeling by 64Cu-Antibody Receptor Targeting for In Vivo Cell Trafficking by PET/CT
Published on: April 29, 2017
A comparison of PET imaging characteristics of various copper radioisotopes
Heather Ann Williams1, Simon Robinson, Peter Julyan
1Christie Hospital NHS Trust, North Western Medical Physics, Wilmslow Road, Manchester, M20 4BX, United Kingdom. hwilliams@physics.org
Purpose:
PET radiotracers which incorporate longer-lived radionuclides enable biological processes to be studied over many hours, at centres remote from a cyclotron. This paper examines the radioisotope characteristics, imaging performance, radiation dosimetry and production modes of the four copper radioisotopes, ( 60)Cu,( 61)Cu,( 62)Cu and( 64)Cu, to assess their merits for different PET imaging applications.
Methods:
Spatial resolution, sensitivity, scatter fraction and noise-equivalent count rate (NEC) are predicted for( 60)Cu,( 61)Cu,( 62)Cu and( 64)Cu using a model incorporating radionuclide decay properties and scanner parameters for the GE Advance scanner. Dosimetry for( 60)Cu,( 61)Cu and( 64)Cu is performed using the MIRD model and published biodistribution data for copper(II) pyruvaldehyde bis(N(4)-methyl)thiosemicarbazone (Cu-PTSM).
Results:
(60)Cu and( 62)Cu are characterised by shorter half-lives and higher sensitivity and NEC, making them more suitable for studying the faster kinetics of small molecules, such as Cu-PTSM.( 61)Cu and( 64)Cu have longer half-lives, enabling studies of the slower kinetics of cells and peptides and prolonged imaging to compensate for lower sensitivity, together with better spatial resolution, which partially compensates for loss of image contrast.( 61)Cu-PTSM and( 64)Cu-PTSM are associated with radiation doses similar to [(18)F]-fluorodeoxyglucose, whilst the doses for( 60)Cu-PTSM and( 62)Cu-PTSM are lower and more comparable with H(2) (15)O.
Conclusion:
The physical and radiochemical characteristics of the four copper isotopes make each more suited to some imaging tasks than others. The results presented here assist in selecting the preferred radioisotope for a given imaging application, and illustrate a strategy which can be extended to the majority of novel PET tracers.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET