Quality control of tablets by Near Infrared (NIR)-Spectroscopy

J Petri1, A Kaunzinger, A Niemöller

  • 1Central Laboratory of German Pharmacists, Eschborn, Germany.

Die Pharmazie
|November 2, 2005
PubMed

Related Concept Videos

Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Applications of IR Spectroscopy: Overview01:11

Applications of IR Spectroscopy: Overview

The non-destructive nature and ability to provide valuable chemical information make IR spectroscopy a versatile technique with broad applications in various scientific and industrial fields. IR spectroscopy is commonly used to identify and characterize organic and inorganic compounds. It provides information about the functional groups present in a molecule and the bonding between atoms. This helps in the structural elucidation of compounds during organic synthesis, pharmaceutical research,...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...
IR Spectrum Peak Intensity: Amount of IR-Active Bonds00:55

IR Spectrum Peak Intensity: Amount of IR-Active Bonds

When infrared radiation is passed through a molecule, absorption occurs if the molecule's vibration leads to a substantial change in its bond dipole moment. Transitions between vibrational energy levels, typically corresponding to infrared frequencies (4000–400 cm−1), allow absorption if the vibration significantly alters the dipole moment, making the molecule infrared active. The molecular bonds have different stretching and bending vibrations, resulting in various peaks with varying...