Related Experiment Video
Updated: Aug 15, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Comparison of PAEE from combined and separate heart rate and movement models in children
Kirsten Corder1, Søren Brage, Nicholas J Wareham
1Medical Research Council Epidemiology Unit, University of Cambridge, Cambridge, United Kingdom.
Purpose:
Accurate measurement of physical activity in children is a challenge. Combining physiological (e.g., heart rate (HR)) and body movement registration (e.g., accelerometry) may overcome limitations with either method used alone. This study aimed to compare the estimated physical activity energy expenditure (PAEE) from hip- and ankle-mounted MTI Actigraphs, a hip-mounted Actical, and a new combined HR and movement sensor, the Actiheart (Cambridge Neurotechnology, Papworth, UK).
Methods:
Resting EE and submaximal EE (treadmill walking and running) were measured in 39 children (13.2 +/- 0.3 yr) by indirect calorimetry during a progressive treadmill exercise bout. Associations between monitor outputs (activity counts, HR, and activity counts + HR) and the criterion were examined by linear regression models. The agreement between measured and predicted PAEE was examined by modified Bland-Altman plots in a subsample of participants.
Results:
The combined Actiheart model (activity counts + HR) had the strongest relationship with PAEE (R2 = 0.86), compared with those from the single-measure models (R2 = 0.69 and 0.82 for the activity model and HR model). The explained variances from the other activity monitors were lower (R2 = 0.50, 0.37, and 0.67) for the hip MTI, ankle MTI, and Actical, respectively. In cross-validation analyses, significant correlations were observed between estimation errors of the methods with the criterion (r = 0.49 to 0.90) in all models using only activity counts indicating a large systematic error. The HR and combined models indicated less systematic error (r = 0.41 and 0.33, respectively).
Conclusions:
Of the techniques considered, combined HR and movement sensing is the most valid for estimating PAEE in children during treadmill walking and running, compared with movement or HR alone. It also has the lowest level of systematic error.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...