Potential of an intracardiac electrogram for the rapid detection of coronary artery occlusion
Tim A Fischell1, David R Fischell, Robert E Fischell
1Borgess Heart Institute, Kalamazoo, MI 49048, USA. taf1@net-link.net
Background:
Early identification of acute MI and prompt intervention can improve clinical outcomes. It would be valuable to identify a method that could allow the earliest possible detection of myocardial injury or ischemia.
Methods And Results:
This article reports one of the first clinical investigations to examine the ability of an intracardiac right ventricular (RV) electrode to identify the early onset of myocardial ischemia/injury in a cohort of patients undergoing balloon occlusion of a coronary artery during percutaneous transluminal coronary angioplasty. The primary data set for analysis included observations from 14 patients with 17 lesions, with a matched comparison of a V6 surface lead and the RV to left upper chest, "intracardiac" lead. The intracardiac lead was sensitive in detecting myocardial injury current/ischemia. There was a 36.4+/-5.6% ST-segment shift, relative to the amplitude of the QRS complex, in the intracardiac lead at 2 min, compared with a 10.1+/-1.9% ST shift from a surface lead (P=.00011). The RV to left upper chest lead detected a >10% shift in ST segment within 2 min in 17 (100%) of 17 cases vs. 8 (47%) of 17 for a V6 surface lead. The intracardiac lead provided detection of ischemia in all three major epicardial coronary distributions.
Conclusions:
This study demonstrates the ability of an intracardiac (RV apex to left upper chest) lead to rapidly detect myocardial ischemia/injury during acute coronary occlusion in the setting of balloon angioplasty. The results of this study suggest that a simple implantable system resembling a ventricular pacemaker could be programmed to assist in the very early diagnosis of acute myocardial infarction.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Acute Coronary Syndrome III: Diagnostic Studies
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...