Estimation of radiation dose received during treatment of in-stent restenosis using ionizing radiation
Lisa Cole Dimmick1, Billy Bass, Ron Waksman
1Georgetown University, Washington, DC 20057, USA. dimmick@nucusa.com
Background:
Angioplasty is a widely accepted procedure for the treatment of coronary artery disease. However, restenosis of the treated vessel occurs in 30% of patients within 6 months. Intravascular brachytherapy (IVB) is used to inhibit the formation of new tissue growth at the vessel treatment site. IVB protocols using either gamma ray or beta particle emitting isotopes have been tested and approved. However, very little data are available on resultant whole-body dose and the potential for long-term radiation effects.
Methods:
Using thermoluminescence dosimetry (TLD) devices, specifically lithium fluoride (LiF) doped with Mg, Cu, and P, the radiation dose on the surface of patients undergoing IVB was measured. The TLDs were positioned on the body to obtain a measure of the gamma dose at selected anatomic locations. Additionally, the skin dose from fluoroscopy was estimated.
Results:
Measurements indicate that the average body dose on the skin surface from all TLDs, clinical requirements, and gamma source configurations varies from 0.95 mSv (95 mrem) at the head to 27.06 mSv (2706 mrem) at the sternal notch. For beta sources, the dose varied from 0.11 mSv (11.4 mrem) at the head to 0.49 mSv (49.5 mrem) at the sternal notch. The fluoroscopy contribution of dose to the body dose (15-min exposure time) was 0.10 mSv (10 mrem) at the head and 2.57 mSv (257 mrem) to the sternal notch.
Conclusions:
The results suggest that surface skin exposures from gamma sources used in IVB pose acceptable risks considering the medical benefits of the procedures.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...