Related Experiment Video
Updated: Aug 15, 2026

Impact of Intracardiac Neurons on Cardiac Electrophysiology and Arrhythmogenesis in an Ex Vivo Langendorff System
Published on: May 22, 2018
Single heartbeat cardiac tagging for the evaluation of transient phenomena
Daniel A Herzka1, J Andrew Derbyshire, Peter Kellman
1Department of Biomedical Engineering, Johns Hopkins University School of Medicine Baltimore, Maryland 20892-1061, USA. herzkad@nih.gov
Abstract:
Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heartbeat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and inter-heartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:39Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm